• <th id="abimu"></th>

      1. 產(chǎn)品中心

        人組織因子(TF)酶聯(lián)免疫吸附檢測試劑盒
        ELK9399
        規(guī)格: 價格:
        48T ¥1960.00
        96T ¥2800.00

        Overview 文獻(xiàn)

        Product name: Human TF(Tissue Factor) ELISA Kit
        Reactivity: Human
        Alternative Names: CD142; FIII; F3; TFA; Thromboplastin; Coagulation Factor III
        Assay Type: Sandwich
        Sensitivity: 2.63 pg/mL
        Standard: 400 pg/mL
        Detection Range: 6.25-400 pg/mL
        Sample Type: plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
        Assay Length: 3.5h
        Research Area: Hematology;Cardiovascular biology;
        Uniprot ID: P13726
        Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human TF. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human TF. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human TF, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human TF in the samples is then determined by comparing the OD of the samples to the standard curve.

        標(biāo)準(zhǔn)曲線

        Concentration (pg/mL) OD Corrected OD
        400.00 2.035 1.948
        200.00 1.663 1.576
        100.00 1.128 1.041
        50.00 0.907 0.820
        25.00 0.532 0.445
        12.50 0.305 0.218
        6.25 0.258 0.171
        0.00 0.087 0.000

        精密度

        Intra-assay Precision (Precision within an assay):CV%<8%

        Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

        Inter-assay Precision (Precision between assays):CV%<10%

        Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

        回收率

        Matrices listed below were spiked with certain level of recombinant TF and the recovery rates were calculated by comparing the measured value to the expected amount of TF in samples.
        Matrix Recovery range Average
        serum(n=5) 85-97% 91%
        EDTA plasma(n=5) 80-97% 88%
        Heparin plasma(n=5) 93-101% 97%

        線性

        The linearity of the kit was assayed by testing samples spiked with appropriate concentration of TF and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
        Matrix 1:2 1:4 1:8 1:16
        serum(n=5) 95-106% 88-103% 81-98% 78-90%
        EDTA plasma(n=5) 95-102% 95-103% 87-98% 93-105%
        Heparin plasma(n=5) 88-101% 86-97% 87-102% 89-101%