• <th id="abimu"></th>

      1. 產(chǎn)品中心

        甘氨酸(Gly)酶聯(lián)免疫吸附檢測(cè)試劑盒
        ELK8276
        規(guī)格: 價(jià)格:
        48T ¥2240.00
        96T ¥3200.00

        Overview 文獻(xiàn)

        Product name: Gly(Glycine) ELISA Kit
        Reactivity: General
        Alternative Names: Glycine
        Assay Type: Competitive Inhibition
        Sensitivity: 0.55 μg/mL
        Standard: 100 μg/mL
        Detection Range: 1.57-100 μg/mL
        Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
        Assay Length: 2h
        Research Area: Microbiology and biochemistry
        Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Gly protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Gly. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Gly in the samples is then determined by comparing the OD of the samples to the standard curve.

        標(biāo)準(zhǔn)曲線

        Concentration (μg/mL) OD Corrected OD
        100.00 0.191
        50.00 0.352
        25.00 0.611
        12.50 0.833
        6.25 1.236
        3.13 1.439
        1.57 1.793
        0.00 2.057

        精密度

        Intra-assay Precision (Precision within an assay):CV%<8%

        Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

        Inter-assay Precision (Precision between assays):CV%<10%

        Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

        回收率

        Matrices listed below were spiked with certain level of recombinant Gly and the recovery rates were calculated by comparing the measured value to the expected amount of Gly in samples.
        Matrix Recovery range Average
        serum(n=5) 78-93% 85%
        EDTA plasma(n=5) 82-95% 88%
        Heparin plasma(n=5) 89-103% 95%

        線性

        The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Gly and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
        Matrix 1:2 1:4 1:8 1:16
        serum(n=5) 87-90% 87-98% 89-97% 85-94%
        EDTA plasma(n=5) 87-103% 97-105% 79-90% 87-96%
        Heparin plasma(n=5) 95-106% 87-105% 92-101% 79-90%
        關(guān)閉

        在線咨詢

        Online consultation

        • 在線咨詢
        • 技術(shù)支持

        關(guān)注微信公眾號(hào)

        微信掃一掃立即咨詢

        微信掃一掃立即咨詢

        關(guān)閉
        一级a爱片国产亚洲精品,97se亚洲综合色区,日朝欧美亚洲精品,欧洲韩国亚洲一区二区三区

      2. <th id="abimu"></th>