        Product name: Rat LL-37(Antibacterial Protein LL-37) ELISA Kit
        Reactivity: Rat
        Alternative Names: CAP18; FALL39; HSD26; LL37; 18 kDa Cationic Antimicrobial Protein; Antibacterial protein FALL-39; FALL-39 peptide antibiotic; CAMP; Cathelicidin Antimicrobial Peptide
        Assay Type: Sandwich
        Sensitivity: 57 pg/mL
        Standard: 8000 pg/mL
        Detection Range: 125-8000 pg/mL
        Sample Type: serum, plasma and other biological fluids
        Assay Length: 3.5h
        Research Area: Infection immunity;
        Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat LL-37. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat LL-37. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat LL-37, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat LL-37 in the samples is then determined by comparing the OD of the samples to the standard curve.

        標(biāo)準(zhǔn)曲線

        Concentration (pg/mL) OD Corrected OD
        8000.00 2.052 1.965
        4000.00 1.717 1.630
        2000.00 1.282 1.195
        1000.00 0.797 0.710
        500.00 0.535 0.448
        250.00 0.324 0.237
        125.00 0.175 0.088
        0.00 0.087 0.000

        精密度

        Intra-assay Precision (Precision within an assay):CV%<8%

        Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

        Inter-assay Precision (Precision between assays):CV%<10%

        Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

        回收率

        Matrices listed below were spiked with certain level of recombinant LL-37 and the recovery rates were calculated by comparing the measured value to the expected amount of LL-37 in samples.
        Matrix Recovery range Average
        serum(n=5) 81-95% 88%
        EDTA plasma(n=5) 88-102% 95%
        Heparin plasma(n=5) 83-98% 90%

        線性

        The linearity of the kit was assayed by testing samples spiked with appropriate concentration of LL-37 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
        Matrix 1:2 1:4 1:8 1:16
        serum(n=5) 89-101% 79-92% 82-93% 83-97%
        EDTA plasma(n=5) 78-92% 83-96% 95-107% 87-102%
        Heparin plasma(n=5) 88-102% 86-97% 89-97% 79-95%