• <th id="abimu"></th>

      1. 產(chǎn)品中心

        人殺菌肽LL-37(LL-37)酶聯(lián)免疫吸附檢測試劑盒
        ELK8189
        規(guī)格: 價格:
        48T ¥2240.00
        96T ¥3200.00

        Overview 文獻

        Product name: Human LL-37(Antibacterial Protein LL-37) ELISA Kit
        Reactivity: Human
        Alternative Names: CAP18; FALL39; HSD26; LL37; 18 kDa Cationic Antimicrobial Protein; Antibacterial protein FALL-39; FALL-39 peptide antibiotic; CAMP; Cathelicidin Antimicrobial Peptide
        Assay Type: Sandwich
        Sensitivity: 0.27 ng/mL
        Standard: 50 ng/mL
        Detection Range: 0.79-50 ng/mL
        Sample Type: serum, plasma and other biological fluids
        Assay Length: 3.5h
        Research Area: Infection immunity;
        Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human LL-37. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human LL-37. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human LL-37, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human LL-37 in the samples is then determined by comparing the OD of the samples to the standard curve.

        標準曲線

        Concentration (ng/mL) OD Corrected OD
        50.00 2.054 1.971
        25.00 1.587 1.504
        12.50 1.027 0.944
        6.25 0.866 0.783
        3.13 0.509 0.426
        1.57 0.335 0.252
        0.79 0.228 0.145
        0.00 0.083 0.000

        精密度

        Intra-assay Precision (Precision within an assay):CV%<8%

        Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

        Inter-assay Precision (Precision between assays):CV%<10%

        Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

        回收率

        Matrices listed below were spiked with certain level of recombinant LL-37 and the recovery rates were calculated by comparing the measured value to the expected amount of LL-37 in samples.
        Matrix Recovery range Average
        serum(n=5) 82-94% 88%
        EDTA plasma(n=5) 85-97% 91%
        Heparin plasma(n=5) 82-94% 88%

        線性

        The linearity of the kit was assayed by testing samples spiked with appropriate concentration of LL-37 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
        Matrix 1:2 1:4 1:8 1:16
        serum(n=5) 87-98% 83-94% 85-98% 85-97%
        EDTA plasma(n=5) 98-105% 92-101% 85-105% 87-98%
        Heparin plasma(n=5) 85-92% 79-96% 89-100% 85-96%
        關閉

        在線咨詢

        Online consultation

        • 在線咨詢
        • 技術支持

        關注微信公眾號

        微信掃一掃立即咨詢

        微信掃一掃立即咨詢

        關閉
        一级a爱片国产亚洲精品,97se亚洲综合色区,日朝欧美亚洲精品,欧洲韩国亚洲一区二区三区

      2. <th id="abimu"></th>