• <th id="abimu"></th>

      1. 產(chǎn)品中心

        5-羥基吲哚乙酸(5-HIAA)酶聯(lián)免疫吸附檢測(cè)試劑盒
        ELK7838
        規(guī)格: 價(jià)格:
        48T ¥2240.00
        96T ¥3200.00

        Overview 文獻(xiàn)

        Product name: 5-HIAA(5-Hydroxyindoleacetic Acid) ELISA Kit
        Reactivity: General
        Alternative Names: 5HIAA
        Assay Type: Competitive Inhibition
        Sensitivity: 1.93 ng/mL
        Standard: 400 ng/mL
        Detection Range: 6.25-400 ng/mL
        Sample Type: serum, plasma, urine, cerebrospinal fluid and other biological fluids
        Assay Length: 2h
        Research Area: Metabolic pathway;Tumor immunity;Endocrinology;Urology;
        Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with 5-HIAA protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to 5-HIAA. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of 5-HIAA in the samples is then determined by comparing the OD of the samples to the standard curve.

        標(biāo)準(zhǔn)曲線

        Concentration (ng/mL) OD Corrected OD
        400.00 0.199
        200.00 0.352
        100.00 0.577
        50.00 0.895
        25.00 1.139
        12.50 1.578
        6.25 1.789
        0.00 2.115

        精密度

        Intra-assay Precision (Precision within an assay):CV%<8%

        Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

        Inter-assay Precision (Precision between assays):CV%<10%

        Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

        回收率

        Matrices listed below were spiked with certain level of recombinant 5-HIAA and the recovery rates were calculated by comparing the measured value to the expected amount of 5-HIAA in samples.
        Matrix Recovery range Average
        serum(n=5) 90-105% 97%
        EDTA plasma(n=5) 85-97% 91%
        Heparin plasma(n=5) 92-105% 93%

        線性

        The linearity of the kit was assayed by testing samples spiked with appropriate concentration of 5-HIAA and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
        Matrix 1:2 1:4 1:8 1:16
        serum(n=5) 89-97% 85-94% 98-105% 92-101%
        EDTA plasma(n=5) 92-101% 87-98% 85-92% 79-96%
        Heparin plasma(n=5) 89-102% 88-97% 88-104% 97-108%