        大鼠層粘連蛋白(LN)酶聯(lián)免疫吸附檢測(cè)試劑盒
        ELK3050
        規(guī)格: 價(jià)格:
        48T ¥1960.00
        96T ¥2800.00

        Overview 文獻(xiàn)

        Product name: Rat LN(Laminin) ELISA Kit
        Reactivity: Rat
        Alternative Names: LAM
        Assay Type: Sandwich
        Sensitivity: 13.8 pg/mL
        Standard: 2000 pg/mL
        Detection Range: 31.25-2000 pg/mL
        Sample Type: serum, plasma and other biological fluids
        Assay Length: 3.5h
        Research Area: Signal Transduction
        Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat LN. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat LN. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat LN, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat LN in the samples is then determined by comparing the OD of the samples to the standard curve.

        標(biāo)準(zhǔn)曲線

        Concentration (pg/mL) OD Corrected OD
        2000.00 2.056 1.970
        1000.00 1.631 1.545
        500.00 1.106 1.020
        250.00 0.842 0.756
        125.00 0.529 0.443
        62.50 0.332 0.246
        31.25 0.219 0.133
        0.00 0.086 0.000

        精密度

        Intra-assay Precision (Precision within an assay):CV%<8%

        Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

        Inter-assay Precision (Precision between assays):CV%<10%

        Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

        回收率

        Matrices listed below were spiked with certain level of recombinant LN and the recovery rates were calculated by comparing the measured value to the expected amount of LN in samples.
        Matrix Recovery range Average
        serum(n=5) 80-96% 88%
        EDTA plasma(n=5) 87-99% 93%
        Heparin plasma(n=5) 83-99% 95%

        線性

        The linearity of the kit was assayed by testing samples spiked with appropriate concentration of LN and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
        Matrix 1:2 1:4 1:8 1:16
        serum(n=5) 92-105% 82-92% 86-94% 81-95%
        EDTA plasma(n=5) 86-93% 91-104% 87-98% 95-99%
        Heparin plasma(n=5) 85-100% 84-99% 85-97% 88-102%