• <th id="abimu"></th>

      1. 產(chǎn)品中心

        人硫酸肝素蛋白聚糖(HSPG)酶聯(lián)免疫吸附檢測試劑盒
        ELK1959
        規(guī)格: 價格:
        48T ¥1960.00
        96T ¥2800.00

        Overview

        Product name: Human HSPG(Heparan Sulfate Proteoglycan) ELISA Kit
        Reactivity: Human
        Alternative Names: SDC2; HSPG1; SYND2; Fibroglycan; Syndecan 2; Syndecan Proteoglycan 2; Heparan Sulfate Proteoglycan 1,Cell Surface-Associated; Heparan Sulphate Proteoglycan
        Assay Type: Sandwich
        Sensitivity: 5.9 pg/mL
        Standard: 1000 pg/mL
        Detection Range: 15.63-1000 pg/mL
        Sample Type: serum, plasma, tissue homogenates and other biological fluids
        Assay Length: 3.5h
        Research Area: Signal transduction;Metabolic pathway;Tumor immunity;Infection immunity;Developmental science;
        Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human HSPG. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human HSPG. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human HSPG, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human HSPG in the samples is then determined by comparing the OD of the samples to the standard curve.

        標(biāo)準(zhǔn)曲線

        Concentration (pg/mL) OD Corrected OD
        1000.00 1.978 1.885
        500.00 1.576 1.483
        250.00 1.106 1.013
        125.00 0.835 0.742
        62.50 0.473 0.380
        31.25 0.325 0.232
        15.63 0.199 0.106
        0.00 0.093 0.000

        精密度

        Intra-assay Precision (Precision within an assay):CV%<8%

        Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

        Inter-assay Precision (Precision between assays):CV%<10%

        Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

        回收率

        Matrices listed below were spiked with certain level of recombinant HSPG and the recovery rates were calculated by comparing the measured value to the expected amount of HSPG in samples.
        Matrix Recovery range Average
        serum(n=5) 90-105% 97%
        EDTA plasma(n=5) 97-105% 101%
        Heparin plasma(n=5) 95-107% 101%

        線性

        The linearity of the kit was assayed by testing samples spiked with appropriate concentration of HSPG and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
        Matrix 1:2 1:4 1:8 1:16
        serum(n=5) 80-101% 87-96% 96-105% 95-103%
        EDTA plasma(n=5) 87-96% 91-101% 87-98% 89-103%
        Heparin plasma(n=5) 78-92% 79-93% 94-106% 83-97%
        關(guān)閉

        在線咨詢

        Online consultation

        • 在線咨詢
        • 技術(shù)支持

        關(guān)注微信公眾號

        微信掃一掃立即咨詢

        微信掃一掃立即咨詢

        關(guān)閉
        一级a爱片国产亚洲精品,97se亚洲综合色区,日朝欧美亚洲精品,欧洲韩国亚洲一区二区三区

      2. <th id="abimu"></th>