        Overview

        Product name: Human PP13(Placental Protein 13) ELISA Kit
        Reactivity: Human
        Alternative Names: LGALS13; PLAC8; PP13; GAL13; Galectin 13; Galactoside-Binding Soluble Lectin 13; Placental tissue protein 13
        Assay Type: Sandwich
        Sensitivity: 6.3 pg/mL
        Standard: 1000 pg/mL
        Detection Range: 15.63-1000 pg/mL
        Sample Type: serum, plasma, tissue homogenates and other biological fluids
        Assay Length: 3.5h
        Research Area: Enzyme & Kinase;Tumor immunity;Reproductive science;Developmental science;
        Uniprot ID: Q9UHV8
        Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human PP13. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human PP13. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human PP13, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human PP13 in the samples is then determined by comparing the OD of the samples to the standard curve.

        標準曲線

        Concentration (pg/mL) OD Corrected OD
        1000.00 2.266 2.181
        500.00 1.497 1.412
        250.00 1.073 0.988
        125.00 0.839 0.754
        62.50 0.593 0.508
        31.25 0.324 0.239
        15.63 0.179 0.094
        0.00 0.085 0.000

        精密度

        Intra-assay Precision (Precision within an assay):CV%<8%

        Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

        Inter-assay Precision (Precision between assays):CV%<10%

        Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

        回收率

        Matrices listed below were spiked with certain level of recombinant PP13 and the recovery rates were calculated by comparing the measured value to the expected amount of PP13 in samples.
        Matrix Recovery range Average
        serum(n=5) 83-95% 89%
        EDTA plasma(n=5) 87-97% 90%
        Heparin plasma(n=5) 81-95% 88%

        線性

        The linearity of the kit was assayed by testing samples spiked with appropriate concentration of PP13 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
        Matrix 1:2 1:4 1:8 1:16
        serum(n=5) 86-102% 87-96% 89-98% 83-103%
        EDTA plasma(n=5) 85-97% 87-96% 85-96% 85-95%
        Heparin plasma(n=5) 86-100% 93-108% 80-101% 87-96%