• <th id="abimu"></th>

      1. 產(chǎn)品中心

        小鼠谷丙轉(zhuǎn)氨酶(ALT)酶聯(lián)免疫吸附檢測試劑盒
        ELK1921
        規(guī)格: 價(jià)格:
        48T ¥1960.00
        96T ¥2800.00

        Overview 文獻(xiàn)

        Product name: Mouse ALT(Alanine Aminotransferase) ELISA Kit
        Reactivity: Mouse
        Alternative Names: GPT; ALAT; SGPT; AAT1; GPT1; Serum Glutamic Pyruvic Transaminase; Alanine Transaminase; Glutamate pyruvate transaminase 1; Glutamic--alanine transaminase 1
        Assay Type: Sandwich
        Sensitivity: 0.65 U/L
        Standard: 100 U/L
        Detection Range: 1.57-100 U/L
        Sample Type: serum, plasma, tissue homogenates, cell lysates and other biological fluids
        Assay Length: 3.5h
        Research Area: Enzyme & Kinase;Infection immunity;Hepatology;
        Uniprot ID: Q8QZR5
        Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse ALT. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse ALT. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse ALT, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse ALT in the samples is then determined by comparing the OD of the samples to the standard curve.

        標(biāo)準(zhǔn)曲線

        Concentration (U/L) OD Corrected OD
        100.00 2.054 1.986
        50.00 1.624 1.556
        25.00 1.196 1.128
        12.50 0.907 0.839
        6.25 0.518 0.450
        3.13 0.357 0.289
        1.57 0.175 0.107
        0.00 0.068 0.000

        精密度

        Intra-assay Precision (Precision within an assay):CV%<8%

        Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

        Inter-assay Precision (Precision between assays):CV%<10%

        Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

        回收率

        Matrices listed below were spiked with certain level of recombinant ALT and the recovery rates were calculated by comparing the measured value to the expected amount of ALT in samples.
        Matrix Recovery range Average
        serum(n=5) 95-108% 101%
        EDTA plasma(n=5) 80-95% 87%
        Heparin plasma(n=5) 82-97% 89%

        線性

        The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ALT and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
        Matrix 1:2 1:4 1:8 1:16
        serum(n=5) 86-93% 91-105% 87-99% 99-105%
        EDTA plasma(n=5) 86-98% 91-103% 85-97% 87-96%
        Heparin plasma(n=5) 87-95% 85-97% 89-101% 85-97%