• <th id="abimu"></th>

      1. 產品中心

        人激肽釋放酶8(KLK8)酶聯免疫吸附檢測試劑盒
        ELK1851
        規(guī)格: 價格:
        48T ¥1960.00
        96T ¥2800.00

        Overview

        Product name: Human KLK8(Kallikrein 8) ELISA Kit
        Reactivity: Human
        Alternative Names: NP; HNP; NRPN; PRSS19; TADG14; BSP1; Neuropsin; Ovasin; Brain Serine Protease 1; Tumor Associated Differentially Expressed Gene 14; Serine protease 19
        Assay Type: Competitive Inhibition
        Sensitivity: 225.3 pg/mL
        Standard: 50000 pg/mL
        Detection Range: 781.25-50000 pg/mL
        Sample Type: Serum, plasma and other biological fluids.
        Assay Length: 2h
        Research Area: Enzyme & Kinase;Tumor immunity;Neuro science;
        Uniprot ID: O60259
        Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Human KLK8 protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human KLK8. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human KLK8 in the samples is then determined by comparing the OD of the samples to the standard curve.

        標準曲線

        Concentration (pg/mL) OD Corrected OD
        50000.00 0.227
        25000.00 0.357
        12500.00 0.575
        6250.00 0.823
        3125.00 1.112
        1562.50 1.537
        781.25 1.793
        0.00 2.211

        精密度

        Intra-assay Precision (Precision within an assay):CV%<8%

        Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

        Inter-assay Precision (Precision between assays):CV%<10%

        Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

        回收率

        Matrices listed below were spiked with certain level of recombinant KLK8 and the recovery rates were calculated by comparing the measured value to the expected amount of KLK8 in samples.
        Matrix Recovery range Average
        serum(n=5) 92-105% 98%
        EDTA plasma(n=5) 83-95% 89%
        Heparin plasma(n=5) 79-93% 86%

        線性

        The linearity of the kit was assayed by testing samples spiked with appropriate concentration of KLK8 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
        Matrix 1:2 1:4 1:8 1:16
        serum(n=5) 87-95% 85-96% 92-102% 81-92%
        EDTA plasma(n=5) 83-97% 92-103% 87-98% 93-101%
        Heparin plasma(n=5) 95-106% 87-101% 82-97% 87-102%