        Overview

        Product name: Human FPA(Fibrinopeptide A) ELISA Kit
        Reactivity: Human
        Alternative Names: FP-A
        Assay Type: Competitive Inhibition
        Sensitivity: 0.55 ng/mL
        Standard: 100 ng/mL
        Detection Range: 1.57-100 ng/mL
        Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
        Assay Length: 2h
        Research Area: Signal transduction;Hematology;
        Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Human FPA protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human FPA. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human FPA in the samples is then determined by comparing the OD of the samples to the standard curve.

        標(biāo)準(zhǔn)曲線

        Concentration (ng/mL) OD Corrected OD
        100.00 0.191
        50.00 0.336
        25.00 0.446
        12.50 0.846
        6.25 1.389
        3.13 1.201
        1.57 1.769
        0.00 2.028

        精密度

        Intra-assay Precision (Precision within an assay):CV%<8%

        Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

        Inter-assay Precision (Precision between assays):CV%<10%

        Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

        回收率

        Matrices listed below were spiked with certain level of recombinant FPA and the recovery rates were calculated by comparing the measured value to the expected amount of FPA in samples.
        Matrix Recovery range Average
        serum(n=5) 96-109% 102%
        EDTA plasma(n=5) 81-95% 88%
        Heparin plasma(n=5) 85-97% 91%

        線性

        The linearity of the kit was assayed by testing samples spiked with appropriate concentration of FPA and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
        Matrix 1:2 1:4 1:8 1:16
        serum(n=5) 85-94% 79-96% 92-101% 83-90%
        EDTA plasma(n=5) 95-102% 93-101% 97-105% 95-103%
        Heparin plasma(n=5) 91-101% 87-98% 89-103% 81-96%