• <th id="abimu"></th>

      1. 產(chǎn)品中心

        人VGF神經(jīng)生長因子誘導蛋白(VGF)酶聯(lián)免疫吸附檢測試劑盒
        ELK1798
        規(guī)格: 價格:
        48T ¥1960.00
        96T ¥2800.00

        Overview

        Product name: Human VGF(VGF Nerve Growth Factor Inducible) ELISA Kit
        Reactivity: Human
        Alternative Names: NERP1; NERP2; Neuro-Endocrine Specific Protein VGF; Neuroendocrine Regulatory Peptide
        Assay Type: Sandwich
        Sensitivity: 28 pg/mL
        Standard: 5000 pg/mL
        Detection Range: 78.13-5000 pg/mL
        Sample Type: serum, plasma, cerebrospinal fluid and other biological fluids
        Assay Length: 3.5h
        Research Area: Metabolic pathway;Infection immunity;Neuro science;
        Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human VGF. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human VGF. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human VGF, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human VGF in the samples is then determined by comparing the OD of the samples to the standard curve.

        標準曲線

        Concentration (pg/mL) OD Corrected OD
        5000.00 1.946 1.851
        2500.00 1.528 1.433
        1250.00 1.186 1.091
        625.00 0.897 0.802
        312.50 0.595 0.500
        156.25 0.335 0.240
        78.13 0.230 0.135
        0.00 0.095 0.000

        精密度

        Intra-assay Precision (Precision within an assay):CV%<8%

        Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

        Inter-assay Precision (Precision between assays):CV%<10%

        Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

        回收率

        Matrices listed below were spiked with certain level of recombinant VGF and the recovery rates were calculated by comparing the measured value to the expected amount of VGF in samples.
        Matrix Recovery range Average
        serum(n=5) 93-107% 100%
        EDTA plasma(n=5) 87-99% 93%
        Heparin plasma(n=5) 80-93% 86%

        線性

        The linearity of the kit was assayed by testing samples spiked with appropriate concentration of VGF and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
        Matrix 1:2 1:4 1:8 1:16
        serum(n=5) 86-95% 82-93% 97-106% 89-102%
        EDTA plasma(n=5) 78-95% 96-103% 83-101% 82-97%
        Heparin plasma(n=5) 85-94% 97-103% 79-91% 82-91%
        關(guān)閉

        在線咨詢

        Online consultation

        • 在線咨詢
        • 技術(shù)支持

        關(guān)注微信公眾號

        微信掃一掃立即咨詢

        微信掃一掃立即咨詢

        關(guān)閉
        一级a爱片国产亚洲精品,97se亚洲综合色区,日朝欧美亚洲精品,欧洲韩国亚洲一区二区三区

      2. <th id="abimu"></th>