• <th id="abimu"></th>

      1. 產(chǎn)品中心

        人血小板反應(yīng)蛋白1(TSP-1)酶聯(lián)免疫吸附檢測(cè)試劑盒
        ELK1685
        規(guī)格: 價(jià)格:
        48T ¥1960.00
        96T ¥2800.00

        Overview

        Product name: Human TSP-1(Thrombospondin-1) ELISA Kit
        Reactivity: Human
        Alternative Names: TSP1; Thrombospondin-1p180; THBS1; Thrombospondin 1
        Assay Type: Sandwich
        Sensitivity: 53 pg/mL
        Standard: 8000 pg/mL
        Detection Range: 125-8000 pg/mL
        Sample Type: plasma
        Assay Length: 3.5h
        Research Area: Infection immunity;Hematology;
        Uniprot ID: P07996
        Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human TSP-1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human TSP-1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human TSP-1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human TSP-1 in the samples is then determined by comparing the OD of the samples to the standard curve.

        標(biāo)準(zhǔn)曲線

        Concentration (pg/mL) OD Corrected OD
        8000.00 2.164 2.040
        4000.00 1.782 1.658
        2000.00 1.205 1.081
        1000.00 0.963 0.839
        500.00 0.547 0.423
        250.00 0.339 0.215
        125.00 0.227 0.103
        0.00 0.124 0.000

        精密度

        Intra-assay Precision (Precision within an assay):CV%<8%

        Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

        Inter-assay Precision (Precision between assays):CV%<10%

        Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

        回收率

        Matrices listed below were spiked with certain level of recombinant TSP-1 and the recovery rates were calculated by comparing the measured value to the expected amount of TSP-1 in samples.
        Matrix Recovery range Average
        serum(n=5) 85-99% 92%
        EDTA plasma(n=5) 93-107% 100%
        Heparin plasma(n=5) 87-99% 93%

        線性

        The linearity of the kit was assayed by testing samples spiked with appropriate concentration of TSP-1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
        Matrix 1:2 1:4 1:8 1:16
        serum(n=5) 86-97% 93-105% 82-93% 95-104%
        EDTA plasma(n=5) 87-96% 85-97% 85-94% 87-96%
        Heparin plasma(n=5) 93-104% 83-96% 95-103% 88-95%