Rat HSPD1(Heat Shock 60kD Protein 1, Chaperonin) ELISA Kit
Reactivity:
Rat
Alternative Names:
HSP60; GROEL; CPN60; HuCHA60; Heat Shock Protein 60; Spastic Paraplegia 13,Autosomal Dominant; 60 kDa chaperonin; Mitochondrial matrix protein P1; P60 lymphocyte protein
Assay Type:
Sandwich
Sensitivity:
0.65 ng/mL
Standard:
100 ng/mL
Detection Range:
1.57-100 ng/mL
Sample Type:
serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.
Assay Length:
3.5h
Research Area:
Signal transduction;Tumor immunity;
Uniprot ID:
P63039
Test principle:
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat HSPD1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat HSPD1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat HSPD1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat HSPD1 in the samples is then determined by comparing the OD of the samples to the standard curve.
標(biāo)準(zhǔn)曲線(xiàn)
Concentration (ng/mL)
OD
Corrected OD
100.00
1.946
1.850
50.00
1.528
1.432
25.00
1.282
1.186
12.50
0.864
0.768
6.25
0.535
0.439
3.13
0.389
0.293
1.57
0.221
0.125
0.00
0.096
0.000
精密度
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
回收率
Matrices listed below were spiked with certain level of recombinant HSPD1 and the recovery rates were calculated by comparing the measured value to the expected amount of HSPD1 in samples.
Matrix
Recovery range
Average
serum(n=5)
78-93%
85%
EDTA plasma(n=5)
90-105%
97%
Heparin plasma(n=5)
87-99%
93%
線(xiàn)性
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of HSPD1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.