• <th id="abimu"></th>

      1. 產(chǎn)品中心

        人B-淋巴細(xì)胞激活抗原B7-2(LAB7-2)酶聯(lián)免疫吸附檢測(cè)試劑盒
        ELK1606
        規(guī)格: 價(jià)格:
        48T ¥1960.00
        96T ¥2800.00

        Overview

        Product name: Human LAB7-2(B-Lymphocyte Activation Antigen B7-2) ELISA Kit
        Reactivity: Human
        Alternative Names: CD86; B7-2; B70; FUN-1; CD28LG2; CD28 Antigen Ligand 2,B7-2 Antigen; CTLA-4 counter-receptor B7.2
        Assay Type: Sandwich
        Sensitivity: 0.274 ng/mL
        Standard: 10 ng/mL
        Detection Range: 0.16-10 ng/mL
        Sample Type: Tissue homogenates, cell lysates, cell culture supernates and other biological fluids
        Assay Length: 3.5h
        Research Area: Signal transduction;CD & Adhesion molecule;Tumor immunity;Infection immunity;Immune molecule;
        Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human LAB7-2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human LAB7-2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human LAB7-2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human LAB7-2 in the samples is then determined by comparing the OD of the samples to the standard curve.

        標(biāo)準(zhǔn)曲線

        Concentration (ng/mL) OD Corrected OD
        10.00 2.131 2.036
        5.00 1.563 1.468
        2.50 1.251 1.156
        1.25 0.896 0.801
        0.63 0.453 0.358
        0.32 0.335 0.240
        0.16 0.230 0.135
        0.00 0.095 0.000

        精密度

        Intra-assay Precision (Precision within an assay):CV%<8%

        Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

        Inter-assay Precision (Precision between assays):CV%<10%

        Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

        回收率

        Matrices listed below were spiked with certain level of recombinant LAB7-2 and the recovery rates were calculated by comparing the measured value to the expected amount of LAB7-2 in samples.
        Matrix Recovery range Average
        serum(n=5) 92-105% 98%
        EDTA plasma(n=5) 82-95% 88%
        Heparin plasma(n=5) 85-97% 91%

        線性

        The linearity of the kit was assayed by testing samples spiked with appropriate concentration of LAB7-2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
        Matrix 1:2 1:4 1:8 1:16
        serum(n=5) 82-94% 85-97% 91-102% 81-90%
        EDTA plasma(n=5) 78-92% 82-96% 86-99% 93-101%
        Heparin plasma(n=5) 85-96% 86-98% 92-103% 87-93%
        關(guān)閉

        在線咨詢

        Online consultation

        • 在線咨詢
        • 技術(shù)支持

        關(guān)注微信公眾號(hào)

        微信掃一掃立即咨詢

        微信掃一掃立即咨詢

        關(guān)閉
        一级a爱片国产亚洲精品,97se亚洲综合色区,日朝欧美亚洲精品,欧洲韩国亚洲一区二区三区

      2. <th id="abimu"></th>