• <th id="abimu"></th>

      1. 產(chǎn)品中心

        人白介素37(IL37)酶聯(lián)免疫吸附檢測試劑盒
        ELK1343
        規(guī)格: 價格:
        48T ¥1680.00
        96T ¥2400.00

        Overview

        Product name: Human IL-37(Interleukin 37) ELISA Kit
        Reactivity: Human
        Alternative Names: IL-1Z;IL1 Zeta; IL1F7; IL37; FIL1; FIL1(ZETA); FIL1Z; IL-1F7; IL-1H4; IL-1RP1; IL1H4; IL1RP1; Interleukin 37; Interleukin-1-Related Protein; Interleukin 1 Family; Member 7
        Assay Type: Sandwich
        Sensitivity: 3.3 pg/mL
        Standard: 500 pg/mL
        Detection Range: 7.82-500 pg/mL
        Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
        Assay Length: 3.5h
        Research Area: Cytokine;
        Uniprot ID: Q9NZH6
        Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human IL-37. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human IL-37. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human IL-37, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human IL-37 in the samples is then determined by comparing the OD of the samples to the standard curve.

        標準曲線

        Concentration (pg/mL) OD Corrected OD
        500.00 2.172 2.074
        250.00 1.588 1.490
        125.00 1.106 1.008
        62.50 0.835 0.737
        31.25 0.539 0.441
        15.63 0.384 0.286
        7.82 0.247 0.149
        0.00 0.098 0.000

        精密度

        Intra-assay Precision (Precision within an assay):CV%<8%

        Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

        Inter-assay Precision (Precision between assays):CV%<10%

        Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

        回收率

        Matrices listed below were spiked with certain level of recombinant IL-37 and the recovery rates were calculated by comparing the measured value to the expected amount of IL-37 in samples.
        Matrix Recovery range Average
        serum(n=5) 80-97% 88%
        EDTA plasma(n=5) 83-95% 89%
        Heparin plasma(n=5) 81-95% 88%

        線性

        The linearity of the kit was assayed by testing samples spiked with appropriate concentration of IL-37 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
        Matrix 1:2 1:4 1:8 1:16
        serum(n=5) 88-102% 93-105% 91-99% 83-96%
        EDTA plasma(n=5) 79-91% 87-96% 95-103% 85-91%
        Heparin plasma(n=5) 85-92% 90-96% 95-102% 87-98%