• <th id="abimu"></th>

      1. 產(chǎn)品中心

        小鼠D-二聚體(D2D)酶聯(lián)免疫吸附檢測試劑盒
        ELK1311
        規(guī)格: 價格:
        48T ¥1680.00
        96T ¥2400.00

        Overview

        Product name: Mouse D2D(D-Dimer) ELISA Kit
        Reactivity: Mouse
        Alternative Names: D 2 Dimer
        Assay Type: Competitive Inhibition
        Sensitivity: 2.57 ng/mL
        Standard: 500 ng/mL
        Detection Range: 7.82-500 ng/mL
        Sample Type: plasma
        Assay Length: 2h
        Research Area: Hematology;Cardiovascular biology;
        Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Mouse D2D protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse D2D. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse D2D in the samples is then determined by comparing the OD of the samples to the standard curve.

        標(biāo)準(zhǔn)曲線

        Concentration (ng/mL) OD Corrected OD
        500.00 0.197
        250.00 0.397
        125.00 0.612
        62.50 0.899
        31.25 1.157
        15.63 1.589
        7.82 1.733
        0.00 2.157

        精密度

        Intra-assay Precision (Precision within an assay):CV%<8%

        Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

        Inter-assay Precision (Precision between assays):CV%<10%

        Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

        回收率

        Matrices listed below were spiked with certain level of recombinant D2D and the recovery rates were calculated by comparing the measured value to the expected amount of D2D in samples.
        Matrix Recovery range Average
        serum(n=5) 81-95% 88%
        EDTA plasma(n=5) 82-97% 89%
        Heparin plasma(n=5) 95-107% 101%

        線性

        The linearity of the kit was assayed by testing samples spiked with appropriate concentration of D2D and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
        Matrix 1:2 1:4 1:8 1:16
        serum(n=5) 87-98% 92-104% 82-96% 95-102%
        EDTA plasma(n=5) 92-105% 83-92% 89-98% 85-94%
        Heparin plasma(n=5) 86-98% 93-106% 89-97% 85-94%