• <th id="abimu"></th>

      1. 產(chǎn)品中心

        小鼠簇集蛋白(CLU)酶聯(lián)免疫吸附檢測(cè)試劑盒
        ELK1310
        規(guī)格: 價(jià)格:
        48T ¥1680.00
        96T ¥2400.00

        Overview

        Product name: Mouse CLU(Clusterin) ELISA Kit
        Reactivity: Mouse
        Alternative Names: CLU; TRPM2; KUB1; CLI; APOJ; SGP2; AAG4; APO-J; SP-40; Apolipoprotein J; Complement Lysis Inhibitor; 40,Sulfated Glycoprotein 2; Testosterone-Repressed Prostate Message 2
        Assay Type: Sandwich
        Sensitivity: 7.3 ng/mL
        Standard: 1200 ng/mL
        Detection Range: 18.75-1200 ng/mL
        Sample Type: serum, plasma, tissue homogenates, cell lysates,? cell culture supernates and other biological fluids
        Assay Length: 3.5h
        Research Area: Apoptosis;Tumor immunity;Infection immunity;
        Uniprot ID: Q5SW19
        Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse CLU. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse CLU. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse CLU, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse CLU in the samples is then determined by comparing the OD of the samples to the standard curve.

        標(biāo)準(zhǔn)曲線

        Concentration (ng/mL) OD Corrected OD
        1200.00 1.941 1.870
        600.00 1.509 1.438
        300.00 1.069 0.998
        150.00 0.749 0.678
        75.00 0.581 0.510
        37.50 0.315 0.244
        18.75 0.152 0.081
        0.00 0.071 0.000

        精密度

        Intra-assay Precision (Precision within an assay):CV%<8%

        Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

        Inter-assay Precision (Precision between assays):CV%<10%

        Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

        回收率

        Matrices listed below were spiked with certain level of recombinant CLU and the recovery rates were calculated by comparing the measured value to the expected amount of CLU in samples.
        Matrix Recovery range Average
        serum(n=5) 90-105% 97%
        EDTA plasma(n=5) 88-102% 95%
        Heparin plasma(n=5) 80-92% 86%

        線性

        The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CLU and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
        Matrix 1:2 1:4 1:8 1:16
        serum(n=5) 88-97% 86-92% 81-93% 89-105%
        EDTA plasma(n=5) 85-94% 79-96% 92-101% 83-90%
        Heparin plasma(n=5) 95-102% 93-101% 97-105% 95-103%