• <th id="abimu"></th>

      1. 產(chǎn)品中心

        小鼠生長(zhǎng)調(diào)節(jié)致癌基因a(GROa/CXCL1)酶聯(lián)免疫吸附檢測(cè)試劑盒
        ELK1238
        規(guī)格: 價(jià)格:
        48T ¥1680.00
        96T ¥2400.00

        Overview

        Product name: Mouse GROa/CXCL1(Growth Regulated Oncogene Alpha) ELISA Kit
        Reactivity: Mouse
        Alternative Names: CXCL1; GRO1; GROa; GRO-A; MGSA-A; NAP3; SCYB1; Chemokine C-X-C-Motif Ligand 1; Melanoma Growth Stimulating Activity Alpha; Fibroblast Secretory Protein; Neutrophil Activating Protein 3
        Assay Type: Sandwich
        Sensitivity: 6 pg/mL
        Standard: 1000 pg/mL
        Detection Range: 15.63-1000 pg/mL
        Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
        Assay Length: 3.5h
        Research Area: Cytokine;Tumor immunity;Infection immunity;
        Uniprot ID: P12850
        Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse GROa/CXCL1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse GROa/CXCL1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse GROa/CXCL1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse GROa/CXCL1 in the samples is then determined by comparing the OD of the samples to the standard curve.

        標(biāo)準(zhǔn)曲線

        Concentration (pg/mL) OD Corrected OD
        1000.00 2.532 2.429
        500.00 1.617 1.514
        250.00 0.924 0.821
        125.00 0.611 0.508
        62.50 0.476 0.373
        31.25 0.315 0.212
        15.63 0.241 0.138
        0.00 0.103 0.000

        精密度

        Intra-assay Precision (Precision within an assay):CV%<8%

        Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

        Inter-assay Precision (Precision between assays):CV%<10%

        Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

        回收率

        Matrices listed below were spiked with certain level of recombinant GROa/CXCL1 and the recovery rates were calculated by comparing the measured value to the expected amount of GROa/CXCL1 in samples.
        Matrix Recovery range Average
        serum(n=5) 82-95% 88%
        EDTA plasma(n=5) 78-96% 87%
        Heparin plasma(n=5) 95-107% 101%

        線性

        The linearity of the kit was assayed by testing samples spiked with appropriate concentration of GROa/CXCL1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
        Matrix 1:2 1:4 1:8 1:16
        serum(n=5) 79-91% 89-103% 82-95% 86-99%
        EDTA plasma(n=5) 87-96% 91-101% 87-98% 89-103%
        Heparin plasma(n=5) 86-97% 83-96% 91-103% 96-105%
        關(guān)閉

        在線咨詢

        Online consultation

        • 在線咨詢
        • 技術(shù)支持

        關(guān)注微信公眾號(hào)

        微信掃一掃立即咨詢

        微信掃一掃立即咨詢

        關(guān)閉
        一级a爱片国产亚洲精品,97se亚洲综合色区,日朝欧美亚洲精品,欧洲韩国亚洲一区二区三区

      2. <th id="abimu"></th>