      1. 產(chǎn)品中心

        人癌胚抗原(CEA)酶聯(lián)免疫吸附檢測(cè)試劑盒
        ELK1196
        規(guī)格: 價(jià)格:
        48T ¥1680.00
        96T ¥2400.00

        Overview

        Product name: Human CEA(Carcinoembryonic Antigen) ELISA Kit
        Reactivity: Human
        Alternative Names: CD66E; CD66; CEACAM5; Carcinoembryonic Antigen-related Cell Adhesion Molecule 5; Carcinoembryonic Antigen
        Assay Type: Sandwich
        Sensitivity: 7.5 pg/mL
        Standard: 1250 pg/mL
        Detection Range: 19.54-1250 pg/mL
        Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
        Assay Length: 3.5h
        Research Area: Tumor immunity;Gastroenterology;
        Uniprot ID: P06731
        Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CEA. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CEA. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CEA, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CEA in the samples is then determined by comparing the OD of the samples to the standard curve.

        標(biāo)準(zhǔn)曲線

        Concentration (pg/mL) OD Corrected OD
        1250.00 2.075 1.992
        625.00 1.502 1.419
        312.50 1.174 1.091
        156.25 0.797 0.714
        78.13 0.532 0.449
        39.07 0.319 0.236
        19.54 0.179 0.096
        0.00 0.083 0.000

        精密度

        Intra-assay Precision (Precision within an assay):CV%<8%

        Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

        Inter-assay Precision (Precision between assays):CV%<10%

        Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

        回收率

        Matrices listed below were spiked with certain level of recombinant CEA and the recovery rates were calculated by comparing the measured value to the expected amount of CEA in samples.
        Matrix Recovery range Average
        serum(n=5) 91-105% 98%
        EDTA plasma(n=5) 85-97% 91%
        Heparin plasma(n=5) 88-101% 94%

        線性

        The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CEA and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
        Matrix 1:2 1:4 1:8 1:16
        serum(n=5) 85-92% 83-96% 93-102% 87-98%
        EDTA plasma(n=5) 92-103% 93-105% 88-101% 97-106%
        Heparin plasma(n=5) 85-94% 90-99% 95-102% 82-90%