• <th id="abimu"></th>

      1. 產(chǎn)品中心

        人巨噬細(xì)胞來源趨化因子(MDC)酶聯(lián)免疫吸附檢測(cè)試劑盒
        ELK1170
        規(guī)格: 價(jià)格:
        48T ¥1680.00
        96T ¥2400.00

        Overview

        Product name: Human MDC(Macrophage Derived Chemokine) ELISA Kit
        Reactivity: Human
        Alternative Names: CCL22; ABCD1; DC/B-CK; SCYA22; STCP1; Chemokine C-C-Motif Ligand 22; Small Inducible Cytokine Subfamily A(Cys-Cys)Member 22; Stimulated T-Cell Chemotactic Protein 1
        Assay Type: Sandwich
        Sensitivity: 28 pg/mL
        Standard: 5000 pg/mL
        Detection Range: 78.13-5000 pg/mL
        Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
        Assay Length: 3.5h
        Research Area: Cytokine;Infection immunity;
        Uniprot ID: O00626
        Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human MDC. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human MDC. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human MDC, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human MDC in the samples is then determined by comparing the OD of the samples to the standard curve.

        標(biāo)準(zhǔn)曲線

        Concentration (pg/mL) OD Corrected OD
        5000.00 2.108 2.025
        2500.00 1.590 1.507
        1250.00 1.106 1.023
        625.00 0.847 0.764
        312.50 0.581 0.498
        156.25 0.314 0.231
        78.13 0.251 0.168
        0.00 0.083 0.000

        精密度

        Intra-assay Precision (Precision within an assay):CV%<8%

        Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

        Inter-assay Precision (Precision between assays):CV%<10%

        Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

        回收率

        Matrices listed below were spiked with certain level of recombinant MDC and the recovery rates were calculated by comparing the measured value to the expected amount of MDC in samples.
        Matrix Recovery range Average
        serum(n=5) 78-96% 87%
        EDTA plasma(n=5) 80-95% 87%
        Heparin plasma(n=5) 78-92% 85%

        線性

        The linearity of the kit was assayed by testing samples spiked with appropriate concentration of MDC and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
        Matrix 1:2 1:4 1:8 1:16
        serum(n=5) 82-96% 85-98% 95-104% 82-96%
        EDTA plasma(n=5) 85-96% 87-101% 89-97% 85-94%
        Heparin plasma(n=5) 86-99% 93-107% 85-94% 87-101%