        Overview

        Product name: Mouse CEA(Carcinoembryonic Antigen) ELISA Kit
        Reactivity: Mouse
        Alternative Names: CD66E; CD66; CEACAM5; Carcinoembryonic Antigen-related Cell Adhesion Molecule 5; Carcinoembryonic Antigen
        Assay Type: Sandwich
        Sensitivity: 12.9 pg/mL
        Standard: 2000 pg/mL
        Detection Range: 31.25-2000 pg/mL
        Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
        Assay Length: 3.5h
        Research Area: Tumor immunity;Gastroenterology;
        Uniprot ID: Q3UKK2
        Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse CEA. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse CEA. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse CEA, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse CEA in the samples is then determined by comparing the OD of the samples to the standard curve.

        標(biāo)準(zhǔn)曲線

        Concentration (pg/mL) OD Corrected OD
        2000.00 1.952 1.857
        1000.00 1.387 1.292
        500.00 0.913 0.818
        250.00 0.847 0.752
        125.00 0.474 0.379
        62.50 0.302 0.207
        31.25 0.196 0.101
        0.00 0.095 0.000

        精密度

        Intra-assay Precision (Precision within an assay):CV%<8%

        Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

        Inter-assay Precision (Precision between assays):CV%<10%

        Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

        回收率

        Matrices listed below were spiked with certain level of recombinant CEA and the recovery rates were calculated by comparing the measured value to the expected amount of CEA in samples.
        Matrix Recovery range Average
        serum(n=5) 80-96% 88%
        EDTA plasma(n=5) 80-92% 86%
        Heparin plasma(n=5) 78-95% 86%

        線性

        The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CEA and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
        Matrix 1:2 1:4 1:8 1:16
        serum(n=5) 86-95% 85-96% 89-100% 85-96%
        EDTA plasma(n=5) 85-94% 87-101% 86-97% 88-95%
        Heparin plasma(n=5) 92-101% 87-98% 85-92% 79-96%