        Overview

        Product name: Human MPIF2(Myeloid Progenitor Inhibitory Factor 2) ELISA Kit
        Reactivity: Human
        Alternative Names: CCL24; SCYA24; Ckb-6; Eotaxin-2; Chemokine C-C-Motif Ligand 24; Eosinophil chemotactic protein 2; Small Inducible Cytokine Subfamily A(Cys-Cys)Member 24
        Assay Type: Sandwich
        Sensitivity: 6.6 pg/mL
        Standard: 1000 pg/mL
        Detection Range: 15.63-1000 pg/mL
        Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
        Assay Length: 3.5h
        Research Area: Cytokine;Infection immunity;
        Uniprot ID: O00175
        Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human MPIF2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human MPIF2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human MPIF2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human MPIF2 in the samples is then determined by comparing the OD of the samples to the standard curve.

        標準曲線

        Concentration (pg/mL) OD Corrected OD
        1000.00 1.989 1.882
        500.00 1.567 1.460
        250.00 1.198 1.091
        125.00 0.933 0.826
        62.50 0.651 0.544
        31.25 0.335 0.228
        15.63 0.262 0.155
        0.00 0.107 0.000

        精密度

        Intra-assay Precision (Precision within an assay):CV%<8%

        Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

        Inter-assay Precision (Precision between assays):CV%<10%

        Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

        回收率

        Matrices listed below were spiked with certain level of recombinant MPIF2 and the recovery rates were calculated by comparing the measured value to the expected amount of MPIF2 in samples.
        Matrix Recovery range Average
        serum(n=5) 87-99% 93%
        EDTA plasma(n=5) 90-103% 96%
        Heparin plasma(n=5) 78-93% 85%

        線性

        The linearity of the kit was assayed by testing samples spiked with appropriate concentration of MPIF2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
        Matrix 1:2 1:4 1:8 1:16
        serum(n=5) 93-105% 88-102% 87-98% 85-96%
        EDTA plasma(n=5) 97-105% 86-92% 95-103% 92-104%
        Heparin plasma(n=5) 85-94% 92-101% 87-96% 82-90%