• <th id="abimu"></th>

      1. 產(chǎn)品中心

        一步法人血管內(nèi)皮鈣黏蛋白(VE-Cadherin)酶聯(lián)免疫吸附檢測(cè)試劑盒
        ELK088ES
        規(guī)格: 價(jià)格:
        48T ¥1960.00
        96T ¥2800.00

        Overview

        Product name: EasyStep Human VE-Cadherin(Vascular Endothelial Cadherin) ELISA Kit
        Reactivity: Human
        Alternative Names: CD144; 7B4; Cadherin 5 Type 2; VE-Cadherin; Cadherin,Vascular Endothelial; CDH5; Cadherin 5
        Assay Type: Sandwich
        Sensitivity: 32.1 ng/mL
        Standard: 10 μg/mL
        Detection Range: 0.16-10 μg/mL
        Sample Type: Serum, plasma
        Assay Length: 1.5h
        Research Area: CD & Adhesion molecule;Tumor immunity;Infection immunity;
        Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human VE-Cadherin, and the Human VE-Cadherin standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human VE-Cadherin. After TMB substrate solution is added, only those wells that contain Human VE-Cadherin and HRP-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human VE-Cadherin in the samples is then determined by comparing the OD of the samples to the standard curve.

        標(biāo)準(zhǔn)曲線(xiàn)

        Concentration (μg/mL) OD Corrected OD
        10.00 2.075 1.987
        5.00 1.608 1.520
        2.50 1.205 1.117
        1.25 0.852 0.764
        0.63 0.514 0.426
        0.32 0.317 0.229
        0.16 0.252 0.164
        0.00 0.088 0.000

        精密度

        Intra-assay Precision (Precision within an assay):CV%<8%

        Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

        Inter-assay Precision (Precision between assays):CV%<10%

        Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

        回收率

        Matrices listed below were spiked with certain level of recombinant VE-Cadherin and the recovery rates were calculated by comparing the measured value to the expected amount of VE-Cadherin in samples.
        Matrix Recovery range Average
        serum(n=5) 85-97% 91%
        EDTA plasma(n=5) 80-95% 87%
        Heparin plasma(n=5) 89-103% 96%

        線(xiàn)性

        The linearity of the kit was assayed by testing samples spiked with appropriate concentration of VE-Cadherin and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
        Matrix 1:2 1:4 1:8 1:16
        serum(n=5) 87-98% 92-105% 95-107% 82-96%
        EDTA plasma(n=5) 88-97% 86-92% 94-103% 89-97%
        Heparin plasma(n=5) 96-105% 87-96% 90-98% 92-101%