• <th id="abimu"></th>

      1. 產(chǎn)品中心

        一步法人腦鈉素(BNP)酶聯(lián)免疫吸附檢測試劑盒
        ELK007ES
        規(guī)格: 價(jià)格:
        48T ¥2240.00
        96T ¥3200.00

        Overview

        Product name: EasyStep Human BNP(Brain Natriuretic Peptide) ELISA Kit
        Reactivity: Human
        Alternative Names: GC-B; B-Type Natriuretic Peptide; Ventricular Natriuretic Peptide; Gamma-brain natriuretic peptide; Brain natriuretic peptide 32
        Assay Type: Sandwich
        Sensitivity: 6.8 pg/mL
        Standard: 2000 pg/mL
        Detection Range: 31.25-2000 pg/mL
        Sample Type: Serum, plasma
        Assay Length: 1.5h
        Research Area: Cardiovascular biology;Neuro science;Hormone metabolism;
        Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human BNP, and the Human BNP standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human BNP. After TMB substrate solution is added, only those wells that contain Human BNP and HRP-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human BNP in the samples is then determined by comparing the OD of the samples to the standard curve.

        標(biāo)準(zhǔn)曲線

        Concentration (pg/mL) OD Corrected OD
        2000.00 2.266 2.170
        1000.00 1.633 1.537
        500.00 1.088 0.992
        250.00 0.826 0.730
        125.00 0.539 0.443
        62.50 0.313 0.217
        31.25 0.235 0.139
        0.00 0.096 0.000

        精密度

        Intra-assay Precision (Precision within an assay):CV%<8%

        Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

        Inter-assay Precision (Precision between assays):CV%<10%

        Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

        回收率

        Matrices listed below were spiked with certain level of recombinant BNP and the recovery rates were calculated by comparing the measured value to the expected amount of BNP in samples.
        Matrix Recovery range Average
        serum(n=5) 88-102% 95%
        EDTA plasma(n=5) 80-93% 86%
        Heparin plasma(n=5) 87-97% 90%

        線性

        The linearity of the kit was assayed by testing samples spiked with appropriate concentration of BNP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
        Matrix 1:2 1:4 1:8 1:16
        serum(n=5) 87-98% 85-92% 79-96% 89-100%
        EDTA plasma(n=5) 86-102% 87-96% 89-98% 83-103%
        Heparin plasma(n=5) 98-105% 92-101% 85-105% 87-98%

        產(chǎn)品成分表

        關(guān)閉